Applications
Shielded servo cable, used for fixed or mobile installation, with UL CE dual certification.
For servo motor and drive connection system
Wide range of applications (NFPA 70/NEC) compliant with NFPA 79 industrial equipment
EMC anti-electromagnetic interference
Connecting cable between servo controller and motor
Suitable for fixed and mobile applications
Comply with NEC Clause 336, 501 Class 1, Part 2 Field Equipment Installation Project
Industrial machinery and machine tool industry
Advantage
One cable for multiple circuits
Multi-standard certification, reduce inventory types and save costs
Omitting the closed trunking, it is easy to install and save cost (suitable for open wiring)
UL CE dual certification
Oil resistance meets UL OIL RES I & II
Flame retardancy meets CSA FT4 UL
Vertical bridge flame test
-40°C Cold Bend; -25°C Cold Impact; 90°C Wet or Dry
Sunlight resistant, can be buried directly and twisted ±360°
Product structure
Conductor: multiple strands of thin bare copper wire bundled with soft structure conductor, bare copper wire conforming to HAR standard
Insulation: XLPE / TPE /TEEE optional
Power line: black insulation tape marked U/L1/C/L+; V/L2; W/L3/DL-yellow/green grounding protection core wire
Can choose to have 1 pair or 2 pairs of control wires: 1 pair of control wires: black, white; 2 pairs of control wires: black insulated surface with white numbers 5, 6, 7, 8
Cable formation: separate design scheme according to different material numbers: power core wire, without or with one or two separate shielded control pairs, and cabled with short pitch
Shield: tinned copper wire braided shield
Outer sheath: special formula thermoplastic elastomer (TPE)/TPU, orange
Technical Parameters
Operating temperature: fixed installation: -50°C to +80°C (UL/CSA: +80°C)
Mobile installation: -45°C to +80°C (UL/CSA: +80°C)
Bending radius
Mobile installation: 8 × outer diameter
Fixed installation: 5 x outer diameter
Rated voltage
IEC U0/U: 450/750 V
UL/CSA: 600 V
Test cable: 2500V
Burning test: flame retardant, in accordance with IEC 60332-1-2
UL VW-1, cable burning test, CSA FT 1
Non-flammable, in line with IEC 60332-3-22 Class A standard
Core wire identification: color core wire identification, in line with VDE 0293-308
6 cores and above: black core wire white number identification
G = with yellow-green grounding protection core wire
X = without yellow-green grounding protection core wire
Certification standards
Certification: UL CE dual certification